Product Features

Product design: IP67 design, integrated installation, anti-theft, anti-demolition device, temperature sensor installation position, easy to use, actual trip opening, microflow control, communication, etc.

Body: Body is forged with 59-1 brass, full diameter setting, high KVS value; the tilt setting of the flow regulator seat makes the fluid outlet position and inlet position in the same plane, good linearity, does not cause great turbulence, very low noise.

Valve stem: The valve stem is designed by patent technology, the movement stroke and flow rate are completely linear (linear/equivalent percentage); the bottom cone design of valve stem has good small flow sensitivity and long stroke.

Drive: Adopts industrial grade design standard, has strong interference resistance and long-term stability, direct stroke, good interchangeability, short commissioning time, high efficiency, low voltage loss, low noise, smooth operation.W,peak function does not exceed 3W (maximum power consumption for blocking rotation).

Communication transmission: Multiple modes of communication (RS485\WIFI\NB-IoT\Lora can be used), suitable for multiple system architectures, providing flexible applications for multiple system architectures.

Product Function

even distribution
Aiming at different buildings in Dongzhuang District in central heatingHeat and cold unevenness between layer users, through intelligent algorithms.Automatic group control of different floors
The valve stroke, according to the set return water.Temperature value adaptive adjustment of return water network flow rate, achieve flow equalization distribution
It's about creating heat between users on different floors.

The measurements are evenly distributed.

Ultra-energy saving
1.Effectively reduce energy consumption by supplying heat supplyWaste. automatic adjustment of ambient temperature of excavationValve stroke guarantees minimum legal room temperature, rational heating, prevention of oversupply, economical
Use energy.
3.The control center is divided based on real-time data.Determine the cause of the failure (if feedback is used to determine if the pipe is clogged
) remote maintenance, saving lives

cost of labor.

Cloud Control
Real-time monitoring, based on big data analysis,Alert against excessive use of heat, prevent theft of heat, prevent unpaid fees:      

To eliminate thermal contradictions.

Anti-removal
To prevent unprofessional removal of the balance valve